Business

6 Reasons Your Home Isn’t Getting Consistent Hot Water

<Snippet: An inconsistent hot water supply can be quite annoying and draining after a long day at work. There are many reasons for this issue, which we’ve covered in the blog. Read the post to explore these reasons in detail and learn about some popular fixes. >

The lack of hot water can be a major irritant after a tiring day at work, especially in a place like Singapore.

People use hot water pretty frequently to take a bath, due to its therapeutic effects. The water relaxes their muscles, regulates their blood flow, and helps them feel relaxed. A hot water bath also helps them sleep easily and reduces their blood pressure.

So, not getting hot water from your gas water heater in Singapore can be distressing. But why does this problem occur? Let’s explore the reasons and some solutions below.

Why Aren’t You Receiving Hot Water Consistently at Your Home?

You could be facing an inconsistent hot water supply issue at home due to the following issues:

1.    Ignition problems

The ignition problem in your Ferroli gas water could be caused by issues like:

i) a malfunctioning flame detection electrode, which is unable to sense the fire

ii) gas supply issue preventing the gas from reaching the heater

iii) excessive condensation that is affecting the ignition process

It will be denoted by the A01 Ferroli water heater error code. To fix this issue, you should check the gas supply, reset the boiler, and examine the ignition electrode. However, doing so as a novice can damage the heater further.

So, you should call a licensed technician who is certified by the Public Utilities Board and has a Certificate of Statutory Completion.

2.    Overheating protection trip
The overheating protection of your gas water heater in Singapore can trip due to three main reasons. These are:

i) faulty heating sensors

ii) a lack of water circulation:

iii) air present inside the heater.

Let’s explore them briefly below.

IssueReasonHow The Technician Will Fix It
   
Faulty heating sensorsIncorrectly placed within the heater during the manufacturing or installation process.  Correct the placement of the sensor or replace it entirely
Lack of water circulationFaulty or stuck water circulation pumpUnscrew the pump and power the heating to release air and water
Air present inside the heaterLeaks during installationPower off the boiler, open the purge valve lid without unscrewing, bleed radiators, and fill the water up to 2 bars of atmospheric pressure
   

Table 1: Reasons for A03 Errors In Ferroli Gas Water Heaters

3.    Air pressure switch error

An air pressure switch Ferroli water heater errorcan shut down the heater completely and restrict the hot water supply. It can be caused by the air pressure switch being stuck when open or closed, or an obstructed or wrongly sized flue baffle.

The flue baffle is the metal piece in your heater that pushes out the flue gas (waste gas) completely. You should have the air pressure switch replaced to fix this issue. This issue will be denoted by the F07 error code.

See also: Hydrafacial Device: Revolutionizing Skincare for B2B Beauty Businesses

4.    Faulty hot water sensor

A faulty hot water sensor in your Ferroli gas water heater in Singapore leads to an inconsistent or no water supply. It is indicated by the F11 error code and is caused by a damaged or loose wiring between the sensor and PCB.

The technician will fix this issue by examining the sensor for corrosion or damage and cleaning the wiring contacts. If these measures don’t fix anything, the technician checks the sensor resistance and replaces it in case of erroneous readings.

5.    Under supply of electricity

Sometimes, the lack of a proper supply of mains electricity under 170 Volts can affect the overall water heater. This issue is denoted by the F34 error code. The Ferroli water heater technician will check the mains voltage and then choose a water stabiliser if required to fix the issue.

They might also check the PCB and replace it in case of any damage.

6.    Reduced water pressure

Low water pressure inside your Ferroli gas water heater in Singaporeis caused by:

i) partially closed valves

ii) block aerators

iii) corroded pipes

iv) faulty pressure regulators

The technician will fix the issue (denoted by the F37 error code) in the following manner:

IssueHow The Technician Will Fix It
  
Partially Closed ValvesTurning off the gas supply and turning the handle back and forth until the valves stabilize
Blocked AeratorsCleaning the aerator
Corroded PipesReplacing the corroded pipes
Faulty Pressure RegulatorsReplacing the faulty pressure regulators
  

Table 2: Reasons for F37 Errors In Ferroli Gas Water Heaters and How To Fix Them

Concluding Remarks

Your Ferroli gas water heater in Singaporecan produce an inconsistent hot water supply for many other reasons. These include an intervention from the exchanger protection system, faulty gas valves, internal controller errors, or fan problems.

Each of these issues will be denoted by error codes like F43, A09, F50, and F15 error codes, respectively. You should explore these issues by reading your gas heater’s manual and asking a technician for prevention tips.

Want to Enjoy a Steady Supply of Hot Water?

Get in touch with a reputed service provider of Ferroligas water heaters in Singapore, near you, to fix these issues and enjoy a supply of hot water again!